Description
Ready-to-Use Multimode Plate Reader
GloMax® Discover is a ready-to-use multimode plate reader developed with Promega reagent chemistries to provide a simple means of detecting luminescence, fluorescence and absorbance. This advanced plate reader provides flexible use of filters and includes high-performance luminescence, fluorescence, UV-Visible absorbance, BRET and FRET, two-color filtered luminescence and kinetic measurement capabilities. GloMax® Discover can be used as a standalone plate reader or integrated into high-throughput automated workflows. Results are easy to interpret using integrated data analysis software.
Preloaded Protocols for Faster, Easier Data Analysis
Use an assay not listed here?
GloMax® instruments let you install your own custom protocols. No matter what assay you use.
Please feel free to discuss your application/s with our friendly team.
You may also WhatsApp on 0321-8752577
or email support@gomolecular.pk
GloMax® Instruments Come with Dozens of Preloaded Protocols
Complete list of protocols or preloaded for each GloMax® instrument
If you are a young researcher and looking for technical assistance, please feel free to chat on Whatsapp or Email with our friendly team.
It will be totally non-binding and without any obligation to purchase any thing from us.
Complete List of Cell-Based and In Vitro Assay Protocols Available on GloMax®Instruments
GloMax® Application Notes
No need to reinvent the wheel—we’ve already used GloMax® instruments for everything from cell viability, toxicity and metabolism, kinase and cell signaling, reporter gene assays, nucleic acid quantitation for NGS sequencing, PROTACs and protein degradation, bioassays, BRET, ELISAs and even water quality testing. Search our Application Notes collection for examples using GloMax® instruments with a wide range of bioluminescence- and fluorescence-based assays.

- 3D Cell Culture
- Agricultural Research
- Applied & Environmental Sciences
- Biologics
- Cell Based Assays
- CRISPR
- DNA/RNA Analysis
- Drug Discovery
- Food Testing
- Forensics & Human Identification
- Mass Spectrometry
- Molecular Diagnostics
- Protein Expression/Analysis
- Veterinary Science Research
- Viral Infectious Diseases Research
GloMax® plate readers have high sensitivity and a wide dynamic range, so you can detect both high and low signals on the same plate and have confidence in the accuracy of the signal recorded from each well. These instruments provide a range of options for your throughput needs and are equipped with integrated software that makes data analysis easy. GloMax® instruments come preloaded with protocols designed to work seamlessly with a wide variety of Promega luminescent and fluorescence-based assays at the touch of a button.

Easy-to-Use
- Simple touch screen navigation with full PC capabilities
- Choose from over 50 preloaded protocols and spend less time optimizing
- Build custom protocols using the intuitive drag-and-drop interface
- Export data to a network, cloud or any drive desired

Minimal Manual Intervention
- Filter paddles and automatic filter switching allow easy two-color multiplexing assays or kinetic studies
- Quick read-speeds for high efficiencies in your laboratory
- Compatible for 3rd party automation control and data export to LIMS

Superior Sensitivity
- Plate mask (aperture control) for switching between 96-well and 384-well plates
- Low cross-talk between wells gives you better, more usable results
- Broad dynamic range of the instrument extends the linear range of your assay

Quality
- IQ/OQ Service available
- Provides the required technical elements of a part 11 compliant system when used with the appropriate laboratory workflow:
- User Authentication and Authorization
- Data Integrity and Protection
- Electronic Signatures
- Audit Trails
Superior sensitivity so you don’t miss hits
Glomax® microplate readers offer superior sensitivity and auto-gain adjustment letting you measure weak and strong signals on the same plate.
Masking so crosstalk doesn’t mislead your results
The masking design of GloMax® microplate readers means you can be confident that the results from each well are not skewed by signal from neighboring wells.
Broad detection range so you don’t limit your experiments
With the broad detection range of GloMax® microplate readers, you can measure signals ranging from high intensity to near physiological levels.
Design Features
Instrument Specifications
Detection Modes |
Luminescence, Fluorescence Intensity, UV-Visible Absorbance, Filtered Luminescence, BRET and FRET |
Sample Format |
6, 12, 24, 48, 96 and 384-well plates |
Tablet PC |
Windows® 8.1 or 10 Tablet PC with USB connection to instrument |
Read Speed |
96-well plate: less than 1 minute; 384-well plate: less than 3 minutes |
Automation Compatibility |
Hardware and software accessible to 3rd party hardware/software control, including LIMS. |
Dimensions |
18.5in (46.9cm) width 19.5in (46.5cm) depth 10in (25.4cm) height without Tablet and PC mounted 16in (35.5cm) height with Tablet and PC mounted |
Weight |
Approximately 60lbs. (27kg) |
Power Requirements |
120VA, 50/60 HZ |
Warranty |
1-year parts and labor warranty included |
Regulatory Compliance |
For Research Use Only. Not for use in Diagnostic Procedures |
Luminescence Module Specifications
Detector |
Top-reading, head-on photon counting photomultiplier tube (PMT) |
Wavelength Range |
350–700nm |
Detection Limit |
3 × 10-21 moles of luciferase |
Linear Dynamic Range |
9 logs |
Cross-talk |
Less than 3 × 10-5 (white, 96-well plate, Corning 3912) |
Filtered Luminescence |
Built-in filter paddle |
Fluorescence Module Specifications
Detector |
PIN-photodiode |
Light Source |
Wavelength-matched LED |
Read Position |
Top reading |
Wavelengths selection |
Filter module with 5 standard excitation and emission filters. Empty filter positions are available for custom excitation and emission wavelengths. |
Wavelengths included |
UV (Ex: 365nm, Em: 415–445nm) Blue (Ex: 475nm, Em: 500–550nm) Green (Ex: 520nm, Em: 580–640nm) Red (Ex: 627nm, Em: 660–720nm) AFC (Ex: 405nm, Em: 495–505nm) |
Detection Limit |
2fmol fluorescence dye/200µl |
Linear Dynamic Range |
>6 logs (assay dependent) |
UV-Visible Absorbance Module Specifications
Detector |
Top-reading, head-on photon counting photomultiplier tube (PMT) |
Light Source |
Xenon flash lamp |
Spectra Range |
200–600nm |
Filter Wheel |
9 absorbance filters included |
Wavelengths included |
230, 260, 280, 320, 405, 450, 490, 560 and 600nm 10nm band pass |
Detection Limit |
0.1 O.D. |
Dynamic Range |
0–4.0 O.D. |
Injector System Specifications
Number of injectors (optional) |
Two injectors |
Dispense Volume Range |
5–200µl in 1µl increments |
Plate Compatibility |
6, 12, 24, 48, and 96-well plates |
Injection Speed |
20–500µl per second |
Waste Collection Tray Volume |
Approximately 50ml |
Void Volume |
500µl |
Heating System Specifications
Temperature Range | Ambient to 45°C |
Shaker System Specifications
Shaking Pattern | Linear or orbital patterns |
Shaking Intensity | 100–500 cycles/minute |
PC Requirements
Operating System |
Windows® 8.1 or 10 Pro, 64 bit, with USB connection to instrument |
RAM |
2GB |
Disk Space |
64GB |
Other Requirements |
Microsoft.NET 4.0 Framework (full version), Microsoft Excel 2013 Professional |
Available Separately
Product | Catalog # |
---|---|
Luminometer Light Plate | E6531 |
GloMax® Discover Luminescence Filter Paddle | GM3011 |
GloMax® Discover Fluorescence Filter Paddle | GM3012 |
GloMax® Discover 96 Half-Position Aperture Assembly | GM1050 |
GloMax® Dual Injectors with Pumps | GM3030 |
Inner and Outer Injector Tubing, Natural | GM3014 |
GloMax® Explorer Absorbance Module Upgrade | GM3520 |
GloMax® Discover-Explorer Sales Rental | E5301 |
GloMax® Discover or Explorer Installation Qualification | SA1104 |
GloMax® Discover or Explorer Operational Qualification | SA1105 |
GloMax® Discover or Explorer Installation and Operational Qualification | SA1106 |
GloMax® Discover Standard Service Agreement | SA4000 |
GloMax® Discover or Explorer Preventive Maintenance | SA4030 |
Protocols
Quick Protocols
GloMax Discover System Creating a New Protocol FB166
Patents and Disclaimers
Patent Pending.
Resources
Articles
- Measuring Blockade of Immune Checkpoint Targets with Promega Bioassays and GloMax® Discover
- Multiplexing with NanoDLR and CellTiter-Fluor Assays
- Measuring the ADCC Reporter Bioassay Complete Kit (WIL2-S) Signal on the GloMax® Discover System
- Lumit™ Cytokine Assays: Interpolating Data with the GloMax® Discover
Citations
- β-Arrestin1 and 2 differentially regulate PACAP-induced PAC1 receptor signaling and trafficking.—
2018 PLos ONE - See all citations